It comes with two 120 volt hot wires summing up to 240 volts.
Hooking up a 240v outlet. It should run till the end of 240 volt receptacle inside breaker box. Each of the 120v ac outlets in your house uses one of the lines from the 240v pair and one neutral line which has a 0v potential so the total potential at the outlet is 120v. The illustrations show a variety of 240 volt outlets and identify the poles on each. Working with electricity can be dangerous and extreme care.
Push the outlet in front of the wires so the screw holes on the outlet line up with the ones along the sides of the box. Mark the white wire black. If your sheathed cable has a neutral wire and the neutral is not used do not connect it in the circuit panel or in the outlet box. Wiring a 220 240 volt outlet will allow you to run many of today s heavy appliances or garage tools.
Connect the white and black wires to the receptacle terminals. Klein makes the best imo and here s a link to the same ones seen in this video. A large capacity window air conditioner calls for a 20 amp 240 volt receptacle. The 220 volt or as it s called today 240 volt outlet will carry twice as much current as a typical 110 volt outlet used in the home.
Connect the ground wire. Read the circuit breaker s instruction manual to find out how to hook a three wire cable into a 220v breaker. After inserting ground wire to the end of 240 volt receptacle tightly screw it. Just snip it off where it enters the box.
Gentleman how would you like your own personal stripper. Now the wire for ground needs to run through similar bar. I have a 15a 120v single receptacle on a dedicated circuit that used to run my old compressor. If your outlet box is metal be sure to ground the box as well as the appliance.
But we want 240v so we ll have to draw from both lines poles at once. A 240 volt 3 wire receptacle has three prongs two hot and one ground to accept a 3 prong plug. Use a screwdriver to secure the outlet in place so it doesn t come free. Push the wires and outlet into the box so you can screw it in place.
Double pole breaker is basically suitable for 240 volt installation. These are the mains 240v alternating current oscillates between 120v positive and 120v negative. The wires usually are black or red but one may be white if it is labeled as hot with a black or red stripe near each end. I m hooking up an air compressor in my shop it is a dual voltage 8a 240v or 16a 120v.