Outlet Height Ada
A gfci outlet to remain accessible should sit within about 15 to 48 inches from the floor.
Outlet height ada. 15 minimum receptacle height to bottom of outlet box california. The standard height for wall outlet boxes is about 12 inches from the top of the floor covering to the bottom of the receptacle box or 16 inches to the top of the box. 9 low side reach minimum height above floor for ada. If you are setting box heights prior to the installation of the subfloor floor covering or any underlayment be sure to account for this expected height difference.
This would mean 18 from finish floor to the top of the outlet box. Ada says 15 min for receptacles. 14 to center of receptacle above floor in canada higher allowed. The minimum height is 15 inches from the bottom of the receptacle box to the floor and the maximum height is 48 inches.
The ada states that the requirements are to be applied during the design construction additions to and alteration of sites facilities buildings and elements to the extent required by regulations issued by federal agencies under the americans with disabilities act of 1990 ada one of the requirements is access to electrical outlets. 0 min receptacle height above floors indoors. The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010. Deeper shelves extending 20 to 25 inches from the wall reduce the maximum mount ing height of controls and outlets to 44 inches.
I recommend 42 to the top of the box in order to avoid the drywallers filling the box with mud. These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards or standards. I recommend that we all measure 19 to the top from the sub floor. The americans with disabilities act on the other hand specifies 15 inches as the minimum height for a receptacle and 48 to 54 inches as the maximum depending on conditions.
15 minimum receptacle height above floor for ada. Switches outlets and controls in accessible locations for obstructions extending from 0 to 20 inches from the wall the maximum height for a control or outlet over the obstruction is 48 inches above the floor. For switches ada says 48 max. Min 6 1 2 above grade outdoors.
Ada outlet height requirements the americans with disabilities act establishes minimum and maximum heights for outlets and you may want to adhere to ada guidelines when wiring a finished basement. This allows for hardwood floor installation.