California Electrical Code Outlet Spacing
These general guidelines will give you the basics of what electrical inspectors are looking for when they review both remodeling projects and new installations.
California electrical code outlet spacing. This spacing is chosen so that a lamp computer television or other appliance will never be more than 6 feet away from an electrical outlet. Requirements for electrical receptacle outlet or wall plug spacing height and clearances in buildings. Section 210 52 b requires two or more 20 ampere circuits for all receptacle outlets for the small appliance loads including refrigeration equipment in the kitchen. 2016 california electrical code kitchen receptacles and small appliance circuits ground fault circuit interrupters gfci receptacles at kitchens requirements b small appliances.
Receptacles can be spacesd 12 ft. In this article we ll break down the building code for electrical outlets so you can ensure safety and code compliance. Receptacle outlets are not required on a wall directly behind a range counter mounted cooking unit or sink. Spacing outlets more frequently than every 12 feet is of course allowed but it is not required by code.
2016 california electrical code section 210 52 c the following is a list of the general requirements for residential kitchen receptacles based on the 2016 california electrical code. 1 this receptacle does not serve countertop or need gfci protection receptacle max. 2016 california electrical code section 210 52 requires receptacles must be installed so that no point along the counter wall space is more than 24 inches 2 feet measured horizontally from a receptacle outlet. On each side of the receptacle.
In general electrical receptacles are installed along building walls such that at no point along the wall is the distance to the nearest electrical receptacle more than six feet i e. This receptacle not acceptable if it is the only receptacle provided for the appliance. 2016 california electrical code sections 210 52 a 210 60 the following are general requirements for receptacle spacing based on the 2016 ca electrical code. Residential receptacle requirements general 2010 california electrical code fig.
With electrical power and hallways 10 feet or more in length. Electrical codes are in place to protect you the homeowner. Above countertop island or penninsula countertop spaces require only 1 receptacle so the 2 ft 4 ft. Most local codes are based on the national electrical code nec a document that lays out required practices for all aspects of residential and commercial electrical.
This handout is intended to provide only general information for further information contact the building safety division. Because extension cords increase risk. 2010 california electrical code fig.