What Kind Of Electrical Wire Can Be Buried Underground Without Conduit
Rigid metallic conduit is most often used in commercial applications but can be a smart choice for straight runs of wire or cable through an attic garage basement or crawlspace.
What kind of electrical wire can be buried underground without conduit. There are flexible and rigid conduits available. Regulations regarding direct burial cable vary according to local codes usually based on your area s climate and soil conditions. Some municipalities allow you to bury special types of electrical cable below a deck without conduit. The individual electrical conducting wires inside the cable are encased in a solid thermoplastic sheath that seals out moisture and protects the conducting wires within.
Electrical conduit protects and routes electrical wiring. Wiring buried inside rigid metal rmc or intermediate metal imc conduit must have at least 6 inches of earth cover. Both methods have to be gfci ground fault circuit interrupter protected before the wires enter the ground to guard against electrocution in case the wire is accidentally cut while you re digging. Conduits for underground electrical wiring.
Bury uf cables 24 inches below the soil surface and 18 inches deep when protected by 2 inches of concrete. The depth for underground conduit is typically 18 inches depending on the specific installation and project type. Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used. Pvc and rigid conduits are typically used when installing underground electrical wiring.
The terms uf cable and direct bury cable describe types of cable that are suitable for ground contact. Direct burial cable is a special type of electrical wiring or cable that is designed to be buried in a trench underground. When running wires underground through pvc conduit to feed a garage is thhn or thwn the proper type to use. They would use each a red white black and green 8 awg copper conductor but what type of.
Decide how much digging you re prepared to do which determines the type of wire you need to use. For a 6 in deep trench use galvanized rigid metal electrical conduit with individual conductors inside. We recommend the pvc conduit because it offers more protection against physical damage. It can be made of many materials including metal plastic fiber or fired clay.
The type of conduit used is determined by wiring regulations set forth by national and local codes. A second method 12 in. Type uf cable is the most commonly used nonmetallic cable for residential outdoor wiring runs. Electrical cable depth options.
Suppose a garage is to be wired with a subpanel fed from the house by a 40 amp 240v breaker. Uf cable can be direct buried without conduit with a minimum of 24 inches of earth cover. Emt and imc conduits should not be used for underground electrical wiring installations. Wiring in pvc conduit must have at least 18 inches of cover.